Steel Structure Building Manufacturer

Loading

Products

Six Families, One Engineering Standard

The right steel building is not defined by square metres — it is defined by what has to happen inside it. A warehouse is shaped by racking heights and dock sequences; a workshop by cranes and machine loads; a cold store by panel thickness and vapour control; a livestock building by ventilation. Once those internal demands are clear, the frame follows: its span, its eave height, its column grid, its envelope. Each family below is described by the numbers that actually decide cost and performance. If you already know which one fits, follow the card. If not, the selector table further down matches your requirement to a type.

Steel Warehouses

Steel Warehouses

Most warehouse disappointments start with an eave height fixed before the racking design was final. We work backwards from your storage plan — pallet height, aisle width, dock count — to a clear-span frame with doors matched to truck flow.

span 12–40 m eave 6–12 m typhoon & seismic rated
Steel Workshops & Factories

Steel Workshops & Factories

Adding a crane to a frame not designed for one means new columns and new foundations. Foundation pads and connection points for a 5–20 t crane are cast in from day one, with floor loads specified for your process line.

crane 5–20 t machine foundations expansion bays
Aircraft Hangars

Aircraft Hangars

The door is the most expensive moving part of a hangar — and the easiest to get wrong. Door and frame are engineered as one system: sliding or bi-fold, up to 60 m clear opening, with door wind loads solved in the same calculation.

door to 60 m high-wind rated tall eave
Livestock Buildings

Livestock Buildings

Most warehouse disappointments start with an eave height fixed before the racking design was final. We work backwards from your storage plan — pallet height, aisle width, dock count — to a clear-span frame with doors matched to truck flow.

open-ridge ammonia-resistant wash-down
Cold Storage Buildings

Cold Storage Buildings

The failure mode in imported cold stores is condensation at every thermal bridge — not the frame. Thermal-break columns, vapour-sealed junctions and 100 mm+ panels, engineered as one system from +5 °C chiller to −30 °C freezer.

panels 100 mm+ vapour seal +5 °C to −30 °C
Multi-Storey Steel Frames

Multi-Storey Steel Frames

Site quality decides multi-storey projects, so welder skill is removed from the equation: pre-engineered bolted connections, assembled with standard tools and checked against shop drawings — designed to your local seismic code.

bolted connections seismic coded up to [six] storeys

Not sure which type fits? Start here.

Match the requirement to the type — then read the full span tables and load assumptions on its page.

If you need… Look for Type page
High-bay racking and dock doors Eave ≥ 9 m Warehouses
Overhead cranes and heavy machinery Crane beams 5–20 t Workshops & Factories
Aircraft or vehicles through a door wider than 20 m Clear opening to 60 m Aircraft Hangars
Chilled or frozen chambers, 24/7 traffic Panels 100 mm+, vapour seal Cold Storage Buildings
Ventilation for animals Open ridge, curtain walls Livestock Buildings
Multiple floors on tight land Up to [six] storeys Multi-Storey Steel Frames

Why the same square metres are fits? not the same building

Two 2,000 m² buildings can differ by 30% in steel tonnage depending on type. The differences below are where budgets are won or lost — and why every type is quoted from its own engineered layout.

Warehouse vs Workshop

A workshop carries crane beam loads a warehouse never sees: heavier columns, extra bracing, and floor flatness specified for machines. Same footprint, roughly 15–25% more steel.

Cold Store vs Dry Warehouse

A cold store spends its budget in the envelope — panel thickness, vapour sealing, thermal breaks and insulated slab — more than in the frame. Comparing them by m² price compares nothing.

Hangar vs Warehouse

A hangar's defining number is not floor area but clear door opening. A 60 m door is a structural component with its own wind loads, drive system and maintenance life.

Livestock vs Storage

A livestock building trades wall coverage for airflow. Ventilation openings, ridge design and coating selection decide animal health — and the frame's service life.

Delivered examples

Every project page carries the real numbers: span, area, wind class, delivery term.

Fiji Tea Processing Plant

Fiji 750㎡ Tea Factory

Rabasa, North Island
2021-8-9
Philippine Food Factory

Philippines 5508㎡ Food Factory

Davao Region
2021-3-31
North Macedonia Industrial Building

North Macedonia 5400㎡ Industrial Plant

Sintar District, Skopje City
2021-2-19

No drawings yet? You can still start.

Many buyers wait to enquire until they have full drawings. You do not need them. A costed layout starts with four inputs: your land dimensions, what the building must house, the destination site — so we can apply the correct wind, snow and seismic loads — and a target budget. From those, we return a layout with a price and a schedule. Drawings can follow, refined together.

Questions buyers ask before sending drawings

Three numbers separate them: clear height (workshops need more room above the floor), crane provision (5–20 t beams and their column loads), and floor specification (machine foundations and flatness). A warehouse optimises for racking and docks; a workshop optimises for production equipment.

Practically, around 200 m². Below that, fixed costs — engineering, container freight, erection crew mobilisation — push the cost per square metre up quickly, and a conventional structure is usually the better answer.

Both routes exist, but everything is engineered to the site: loads are calculated to the destination building code, and fabrication drawings are issued before any steel is cut. A kit is a starting geometry, never a fixed design.

[3–4] months is typical for a [1,000–2,000] m² building, covering engineering, fabrication and packing. Port lead time and destination country add to this — a costed layout includes the full schedule.

Every delivery includes erection drawings, part numbering and [remote assembly support]. On-site supervision can be arranged for [selected regions] — confirm scope in your quote, because erection support differs by destination.